This video explains how to determine the correct O-ring size for dental implant attachments and reviews practical options for selecting and using O-rings. It covers the two key measurements on a ball abutment—the retention zone and the height of contour—and demonstrates how those dimensions relate to O-ring internal diameter. The discussion also introduces an O-ring sizing chart and a Combo Pack that allows clinicians or laboratory teams to test multiple sizes when direct measurement is impractical. In addition, the video compares open, donut-style housings with closed, domed housings, including the need for blockout and adequate relief when using resilient O-ring attachments. The video concludes with practical guidance on accurate sizing, housing selection, and where to find additional product information and technical support.


Dental Insights
Newsletter

Expert Findings
- The most direct sizing method is to measure the diameter of the retention zone and match that measurement to the O-ring’s internal diameter.
- A ball abutment’s height of contour is generally about 0.4–0.8 mm larger than its retention zone; the example shown pairs a 2.15 mm ball with a 1.4 mm internal-diameter O-ring.
- When intraoral measurement is impractical, the five-size O-ring Combo Pack provides a trial-fit approach with two O-rings of each size.
- Open, donut-style housings require less vertical space but require blockout of the post during processing to prevent contact with acrylic during resilient movement.
- Closed, domed housings occupy more space but eliminate the need for blockout during a chairside pickup, which simplifies the workflow in many cases.
Transcript
In this video, we’re going to talk about O-rings for dental implant attachments, and in particular, how to determine the correct O-ring size.
One of the challenges with dental implant attachments is figuring out which size O-ring you need.
Question: Can you walk me through that process?
Answer: Absolutely. Most of the time, you don’t even need to remove the O-ring from the housing to determine the correct size. We have a couple of helpful tools that make the process much easier. The first step is to get an accurate measurement.
When we look at a ball abutment, there are two key measurements. The first is the diameter of the neck, or undercut, where the O-ring sits. In this example, the retention zone measures 1.4 mm.
Generally, there is about a 0.4 to 0.8 mm difference between the height of contour and the retention zone. So, if the retention zone measures 1.4 mm, the height of contour, or the diameter of the ball, will usually fall somewhere between 1.8 and 2.2 mm.
Question: So that’s what actually keeps the O-ring in place?
Answer: Exactly. This particular ball measures 2.15 mm. If you measured a 2.15 mm diameter ball and needed to determine the correct O-ring, you would subtract approximately 0.4 to 0.8 mm, which tells you that an O-ring with a 1.4 mm internal diameter would be the correct choice.
To make things easier, we provide an O-ring sizing chart in our product catalog, on our mobile app, and on our website. The chart includes five different O-ring sizes and lists both the outer diameter and internal diameter for each.
Simply measure the diameter of the retention zone, match it to the internal diameter of the O-ring, and you’ve identified the correct size.
Question: I imagine using a caliper like this inside the patient’s mouth isn’t very practical.
Answer: Not really. While ball gauges are often used, they aren’t always as accurate as we’d like.
Another option is our O-ring Combo Pack. It includes five different O-ring sizes, with two O-rings of each size. Instead of spending chair time or laboratory time measuring and guessing, you can simply try each size until you find the best fit.
Question: Can you show us how that works?
Answer: Sure. There are two common styles of housings.
The first is the open, donut-style housing. It’s lower profile and requires less vertical space. You simply snap it into place.
The advantage is its compact size, but the downside is that you must block out the top of the post during processing. If you imagine this inside a denture surrounded by acrylic, the first time the patient bites down, the resilient movement of the O-ring attachment will allow the post to move upward. Without proper blockout, the post can contact the acrylic and potentially cause a fracture.
O-ring attachments are among the most resilient attachment systems available. That resiliency helps protect the implant abutments by allowing controlled movement, but it also means you need adequate relief within the prosthesis.
The second option is the closed, domed housing. As you can see, it occupies a little more space, but it eliminates the need for blockout during a chairside pickup, making it a much simpler option in many cases.
If you are using the open housing, one easy way to block out the post is with a plaster slurry. After processing, simply rinse it away with water. It’s much easier to clean up than using soft wax.
Even so, we generally see the closed-style housings used more frequently because of their simplicity.
That covers the basics of O-rings and O-ring sizing. Take your time, make accurate measurements, and you’ll consistently select the proper attachment.
If you’d like more information, visit PREAT.com, where you’ll find product information, educational resources, hundreds of clinical case presentations, and our complete product catalog.
If you have questions, our technical support team and customer service representatives are always available. Give us a call or contact us through the form on our website.
Video Chapters
- 00:00 - How to Determine the Correct O-Ring Size
- 00:25 - How to Measure the Ball Abutment Retention Zone
- 01:10 - How to Use an O-Ring Sizing Chart
- 01:32 - How to Choose an O-Ring When Intraoral Measurement Is Difficult
- 02:02 - Open vs. Closed O-Ring Housings
- 02:50 - Why Blockout and Prosthesis Relief Matter
- 03:28 - O-Ring Sizing Takeaways and Support Resources
Timestamped Narration Sections
00:00–00:19
How do you determine which O-ring size you need?
In this video, we’re going to talk about O-rings for dental implant attachments, and in particular, how to determine the correct O-ring size. One of the challenges with dental implant attachments is figuring out which size O-ring you need. Question: Can you walk me through that process?
00:19–00:38
What is the first step in O-ring sizing?
Answer: Absolutely. Most of the time, you don’t even need to remove the O-ring from the housing to determine the correct size. We have a couple of helpful tools that make the process much easier. The first step is to get an accurate measurement.
00:38–00:53
Which ball abutment measurements matter for O-ring sizing?
When we look at a ball abutment, there are two key measurements. The first is the diameter of the neck, or undercut, where the O-ring sits. In this example, the retention zone measures 1.4 mm.
00:53–01:18
How does the retention zone relate to the ball diameter?
Generally, there is about a 0.4 to 0.8 mm difference between the height of contour and the retention zone. So, if the retention zone measures 1.4 mm, the height of contour, or the diameter of the ball, will usually fall somewhere between 1.8 and 2.2 mm. Question: So that’s what actually keeps the O-ring in place?
01:18–01:40
How do you calculate the correct O-ring from the ball diameter?
Answer: Exactly. This particular ball measures 2.15 mm. If you measured a 2.15 mm diameter ball and needed to determine the correct O-ring, you would subtract approximately 0.4 to 0.8 mm, which tells you that an O-ring with a 1.4 mm internal diameter would be the correct choice.
01:40–02:06
How do you use the O-ring sizing chart?
To make things easier, we provide an O-ring sizing chart in our product catalog, on our mobile app, and on our website. The chart includes five different O-ring sizes and lists both the outer diameter and internal diameter for each. Simply measure the diameter of the retention zone, match it to the internal diameter of the O-ring, and you’ve identified the correct size.
02:06–02:19
What can you do when intraoral measurement is impractical?
Question: I imagine using a caliper like this inside the patient’s mouth isn’t very practical. Answer: Not really. While ball gauges are often used, they aren’t always as accurate as we’d like.
02:19–02:40
How does the O-ring Combo Pack simplify sizing?
Another option is our O-ring Combo Pack. It includes five different O-ring sizes, with two O-rings of each size. Instead of spending chair time or laboratory time measuring and guessing, you can simply try each size until you find the best fit. Question: Can you show us how that works?
02:40–02:52
What are the two common O-ring housing styles?
Answer: Sure. There are two common styles of housings. The first is the open, donut-style housing. It’s lower profile and requires less vertical space. You simply snap it into place.
02:52–03:20
What is the tradeoff with an open, donut-style housing?
The advantage is its compact size, but the downside is that you must block out the top of the post during processing. If you imagine this inside a denture surrounded by acrylic, the first time the patient bites down, the resilient movement of the O-ring attachment will allow the post to move upward. Without proper blockout, the post can contact the acrylic and potentially cause a fracture.
03:20–03:33
Why does an O-ring attachment need adequate relief?
O-ring attachments are among the most resilient attachment systems available. That resiliency helps protect the implant abutments by allowing controlled movement, but it also means you need adequate relief within the prosthesis.
03:33–03:49
What is the advantage of a closed, domed housing?
The second option is the closed, domed housing. As you can see, it occupies a little more space, but it eliminates the need for blockout during a chairside pickup, making it a much simpler option in many cases.
03:49–04:05
How can you block out the post when using an open housing?
If you are using the open housing, one easy way to block out the post is with a plaster slurry. After processing, simply rinse it away with water. It’s much easier to clean up than using soft wax.
04:05–04:11
Which housing style is used more frequently?
Even so, we generally see the closed-style housings used more frequently because of their simplicity.
04:11–04:42
What are the key O-ring sizing takeaways and support options?
That covers the basics of O-rings and O-ring sizing. Take your time, make accurate measurements, and you’ll consistently select the proper attachment. If you’d like more information, visit PREAT.com, where you’ll find product information, educational resources, hundreds of clinical case presentations, and our complete product catalog. If you have questions, our technical support team and customer service representatives are always available. Give us a call or contact us through the form on our website.
- how to determine dental implant O-ring size
- dental implant O-ring sizing chart
- how to measure ball abutment retention zone
- how to choose O-ring for ball abutment
- dental implant O-ring Combo Pack
- open vs closed O-ring housing
- how to block out an O-ring attachment post
- O-ring attachment chairside pickup
- dental implant O-ring housing vertical space